Earthing Design Software Free Download

24.04.2019

• T is defined by “Terre”, which gives a TT system, which is the how the load chassis is grounded to earth using an earthing electrode. • N is defined by “Neutral” which defines the load chassis as connected to neutral. This gives a TN system, which is how the load chassis is connected to earth using either a neutral or a protective earthing (PE) conductor. • The third letter indicate how the neutral and PE conductors are utilized • C is defined by “Combined” which means that the neutral and PE conductors are combined into one conductor (PEN conductor) that acts as the current return conductor during both steady state and fault conditions. Igra karti durak. • S is defined by “Separated” which means that the neutral and PE conductors are separated and independent from each other. • The TN-C-S earthing type has four letters and the fourth letter, just like the third letter, indicates how the neutral and PE conductors are utilized.

The TN-C-S start from the source (such as a utility company) with a combined PEN conductor until a service entry point, e.g. A residential unit, is reached. As soon as the customer’s service entry point is crossed, the earthing conductor will separate into two separate conductors, which are the neutral and the PE conductors. IT System The earthing type for an IT system is marked by using 2 letters and a term: • The first letter, I, is defined by “Isolated” which defines the neutral as is either not connected to earth or indirectly connected to earth through a high impedance. • The second letter, T, is defined by “Terre” which defines the load chassis as connected to earth using an earthing electrode. • The term that follows the IT earthing types are defined as follows: • Individual: The chassis of each load is earthed separately from the neighboring load chassis.

• In Groups: Different loads are separated into groups and then the chassis of each load in a group is interconnected with the other chassis within the same group. The different groups are then earthed individually. • Collective: All of the chassis of all the loads are interconnected and then earthed. Part of the system uses a combined PEN conductor, which is at some point split up into separate PE and N lines. The combined PEN conductor typically occurs between the substation and the entry point into the building, and separated in the service head. In the UK, this system is also known as protective multiple earthing (PME), because of the practice of connecting the combined neutral-and-earth conductor to real earth at many locations, to reduce the risk of broken neutrals - with a similar system in Australia being designated as multiple earthed neutral (MEN).

Earthing Design Software Free DownloadFree

Home / Earthing Design. Help users of SafeGrid Earthing Software to learn about and practice the application of powerful operating principles. Submitted you. No thanks Try it free. Find out why Close. SafeGrid Earthing and Grounding Design Software. SafeGrid earthing design software complies with IEEE Std. 80 and IEC 60479 safety standards.

> Lightning Protection Design Lightning Protection Design We are Lightning Protection Design Consultants. If you have a concern about Lightning striking your high-value or critical asset, then you’re in the right place! Understanding the risks posed from Lightning is a fundamental requirement. “A ship is always safe at the shore - but that is NOT what it is built for.” ― We aim to take ‘Risk’ off the table for your high value critical assets - and in the process present the complexity into an easy-to-understand plan/design or strategy.

Service should mean Service There are many that profess to give good service - but getting the right answer, design or strategy can be a drawn out affair with little in the way of transparent communication. No matter what you need from the our services, you will experience impeccable response so you can get your answers when and how you need them. Ultimate Lighting Protection Design is PREVENTION In Risk Management, PREVENTION is better than cure If cost is not the only concern, then why wait to treat the devastating effects of a lightning strike when you can get to the source of the problem and PREVENT lightning from attaching to your structure!?? If your concern is to take lightning off-the-table as a risk then speak to our research engineers now to see if prevention is practical for you. Not all applications can take a preventative solution, either because the investment premium required over and above a conventional approach cannot be justified, or the structure does not lend itself to a preventative option (these are very rare). For those situations we have the conventional Lightning Protection. Lightning Protection Design - the conventional way, delivered unconventionally GreyMatters has a unique mix of specialist experience covering global lightning protection design solutions in some of the most active regions of the planet.