Mustek Powermust 600 Usb Service Manual
PowerMust 400/600/800 USB User Manual 1. Introduction This UPS is specially designed for Personal Computer with multi-functions. Its light weight, compact design perfect fits to the limited working. Battery when maintenance or service work inside the UPS is necessary.
Driver & Manual Downloads You can select from the Product Name, Type, Operating System and Language in the drop-down menu to specify what to search within. The driver of old products which included Old BearPaw Series, A3 series have been phased out for 10 to 15 years. The drivers for the phased out products will no longer be maintained. Please note, Mustek do not provide technical support and software update service for old products.
You may search the last driver of Mustek old products via the FTP link below. 、、 Please find the path to download the last driver of old products via FTP link above. Path: driver 0_Old_BearPaw Series path: driver 0_Old Products ATTENTION: We strongly recommend you remove the old driver from your computer and then download the correct driver for your scanner, by model name, from Mustek’s FTP.
This post was written by on January 14, 2010 Posted Under:, Introduction I have an old Mustek 600VA UPS with RS-232 connection. Since I change the battery every couple of years on my own, I find it pretty pointless to throw it away. And my brand new computer (running Fedora 12) has an RS-232 port if one insists to use a connector on the motherboard. Needless to say, I had to steal the RS-232 cable from motherboard to panel from an old computer. A simple male/female extension RS-232 cable connects between UPS and computer. PC to UPS communication goes through pin 3, and the other direction through pin 2. The cable should be completely transparent (i.e.
My sister tried to put a video on it and open it on my laptop, but she tried to open it with Windows Media Player. Similar help and support threads Thread Forum THIS TUTORIAL INVOLVES: Docking program (tested on Rocketdock and Objectdock) Stack docklet (I use Stack Docklet For ObjectDock by ~arshi2009 on deviantART on both RD and OD) Link Shell Extension Please choose the appropriate version for your OS. Objectdock stack docklet. 64-bit programs with troublesome shortcuts:p. Software I have a USB drive that turns whatever file or folder you put into it into a shortcut (*.ink) file. Keyboard Logitech wireless K800 Mouse Logitech MX Master PSU Seasonic Prime Titanium 850W Case Thermaltake Core P3 Cooling Corsair Hydro H115i Hard Drives 250GB Samsung 960 EVO M.2 256GB OCZ Vector 6TB WD Black WD6001FZWX Internet Speed 1 Gb/s Download and 35 Mb/s Upload Antivirus Malwarebyte Anti-Malware Premium Browser Google Chrome Other Info Logitech Z625 speaker system * Creative F200 webcam * Lite-On iHBS212 12x BD Writer * Samsung CLX-3175FW Printer * Linksys EA9500 Router * Arris SB8200 Cable Modem * APC SMART-UPS RT 1000 XL.
Not switch wires, in particular not pins 2 and 3). In case you want to see if the UPS is alive with Putty (or some other terminal), go for 2400 baud, 8N1 (8 bits, no flow control and one stop bit). Type Q1 followed by a carriage return, and the UPS should respond with a line of status info. The protocol is described. Linux driver The right driver to run with the UPS is the, or nut for short.
# yum install nut Configure the UPS. # vi /etc/ups/ups.conf Basically, add the following entry: [PowerMust] driver = megatec port=/dev/ttyS0 desc = 'Mustek PowerMust 600VA' mfr = 'Mustek' model = 'PowerMust 600' Now we can kick off the driver which listens to the UPS (the response takes a few seconds): # upsdrvctl start Network UPS Tools - UPS driver controller 2.4.1 Network UPS Tools - Megatec protocol driver 1.6 (2.4.1) Megatec protocol UPS detected. If you happen to have an oscilloscope on the RS-232 lines (ha!), you should see some action every few seconds from now on. Or, alternatively, if you want to see what’s running on the computer, I suggest # ps aux grep nut It so happens, that during the installation, we got a new user, named “nut” under which most of the relevant processes are running.
A process running /sbin/megatec should be found there. Configure the monitor # vi /etc/ups/upsmon.conf Basically, there’s only one line to add (pretty much at the beginning): MONITOR PowerMust@localhost 1 upsmon pass master I’ve chosen to configure the monitor as master, since the I plan to put some virtualization guests, which may work as slaves. As for the “upsmon” and “pass”, these are user and password when connecting to upsd. Since no user nor password were configured in upsd.users, the attempt to login will fail, resulting in error messages when the monitor is started. Now let’s test it. First, let’s remove the already running daemons: # service ups stop Stopping UPS monitor: [FAILED] Stopping upsd: [ OK ] Shutting down upsdrvctl: [ OK ] Stopping the UPS monitor failed, because it wasn’t running.